Quick Install Isolation Rooms

PortaFab Modular Building Systems are an ideal solution for quickly creating temporary, semi-permanent, and permanent isolation rooms within hospitals and medical centers. As a Clean Build alternative to traditional construction, PortaFab’s pre-engineered systems require minimal onsite cutting and fabricating which minimizes contamination threats and helps comply with Class IV ICRA guidelines.


time icon
Quick Install 
no dust icon
Clean Build
clean install icon
Dustless, Clean Installation
 

What is an Airborne Infection Isolation Room?

Also known as negative pressure isolation rooms, airborne infection isolation rooms (AIIR) are used by patients for hospitals and medical centers to prevent cross-contaminations and airborne infections from spreading throughout the facility.

These rooms are commonly recommended by the Center for Disease Control and Prevention (CDC) to help protect the public from diseases and infections that spread easily like tuberculosis, measles, and the coronavirus (COVID-19).

  • Central or point-of-use HEPA filters capable of removing particles 0.3 μm in diameter for supply (incoming) air
  • Well-sealed rooms
    • - Proper construction of windows, doors, and intake and exhaust ports
    • - Smooth, cleanable ceiling tiles
    • - Walls sealed above and below the ceiling
  • Ventilation to maintain ≥12 ACH
  • Directed air flow: design that filters air into one side of room, across patient’s bed and then exits on opposite side of room
  • Self-closing door on all room exits
  • Back-up ventilation equipment

 

Download Brochure

negative pressure cleanroom, cleanrooms, modular cleanrooms, modular cleanroom construction, cleanroom construction, cleanroom, hardwall cleanrooms
 
clean build icon

PortaFab Clean Build System

time icon
Fast & Easy to Install 

Pre-engineered systems can be assembled quickly with minimal training.

clean install icon
Dustless, Clean Installation

Minimal on-site construction and fabrication.

spray icon
Easy to Clean

Smooth, uniform wall surfaces allow for easy disinfection.

blueprint icon
Easy to Configure

Modular components allow for unlimited design potential.

scalable icon
Versatile

Easily expand, relocate or reuse to adjust to changes in demand.

height icon
Class "A" Material

Tested in accordance with ASTM E-84 requirements for flame spread and smoke density.

quality icon
PE Stamped Drawings

Meet stringent construction guidelines including California seismic requirements.

soundproof icon
Sound Deadening

Sound attenuation foam core reduces sound transmission.

Our Wall Systems

PortaFab offers two modular cleanroom systems that can be utilized to help facilities meet these strict CDC standards for negative pressure airborne infection isolation rooms and requirements for ICRA Class IV healthcare construction and renovation projects.

negative pressure cleanroom, cleanrooms, modular cleanrooms, modular cleanroom construction, cleanroom construction, cleanroom, hardwall cleanrooms

F2000 (Gasketed)

PortaFab’s F2000 gasketed wall system is ideal for creating tightly sealed space while still featuring a non-progressive design that allows walls to be relocated without the need to remove adjacent panels, framing studs or ceiling panels.

  • The F2000 system can be outfitted with durable, aluminum-faced wall panels.
  • Maximum Height:  12’
negative pressure cleanroom, cleanrooms, modular cleanrooms, modular cleanroom construction, cleanroom construction, cleanroom, hardwall cleanrooms

Series 300

Our Series 300 wall system features an anodized aluminum stud construction that provides the quality, appearance and cost savings that make conventional construction obsolete. The non-progressive, post-and-panel design provides maximum versatility and relocatability.

  • The Series 300 system can be outfitted with our Aluminum-Faced, Class A, Fire & Sound panels for added performance in healthcare applications.
  • Maximum Height:  17’
 
medical details icon

Integrated Isolation Room Components

negative pressure cleanroom, cleanrooms, modular cleanrooms, modular cleanroom construction, cleanroom construction, cleanroom, hardwall cleanrooms

Walls

PortaFab’s systems utilize aluminum-faced, class A wall panels that are easy-to-clean, non-combustible and provide excellent sound control.

negative pressure cleanroom, cleanrooms, modular cleanrooms, modular cleanroom construction, cleanroom construction, cleanroom, hardwall cleanrooms

Doors

PortaFab’s heavy duty wall systems can accommodate a wide variety of heavy-duty, hospital-grade doors including anti-microbial, stainless steel doors, impact doors and sliding doors for sealing off entire areas.

negative pressure cleanroom, cleanrooms, modular cleanrooms, modular cleanroom construction, cleanroom construction, cleanroom, hardwall cleanrooms

Windows

Multiple window units can be seamlessly integrated into isolation walls including our flush and beveled windows that allow for easy cleaning by eliminating hard-to-clean edges that collect, particles and more.

negative pressure cleanroom, cleanrooms, modular cleanrooms, modular cleanroom construction, cleanroom construction, cleanroom, hardwall cleanrooms

Coving

Radius coving is used to create fully flush corner transitions and seamless wall-to-ceiling and wall-to-floor connections. By eliminating corners, the radius coving system allows for total "cleanability." Wall-to-wall and wall-to-ceiling junctions can be trimmed with an extruded coving that features a large 3" radius.

negative pressure cleanroom, cleanrooms, modular cleanrooms, modular cleanroom construction, cleanroom construction, cleanroom, hardwall cleanrooms

HEPA Filter Units

Rooms can be outfitted with ceiling-mounted fan filter units that are integrated into existing mechanical systems, wall mounted systems or even portable systems like Envirco's Hospi-Gard™ IsoClean™ system shown here.

negative pressure cleanroom, cleanrooms, modular cleanrooms, modular cleanroom construction, cleanroom construction, cleanroom, hardwall cleanrooms

Gasketed Ceiling Grid System

PortaFab wall systems integrate seamlessly with our gasketed, heavy-duty ceiling grid that can support fan filter units, diffusers and light fixtures. The ceiling system creates an air-tight barrier between the space and ceiling plenum to prevent transmission of contaminants into the room.

 
modular walls icon

Get a Quote Today

 

Allow PortaFab to assist you with the design, construction and installation of a negative pressure airborne infection isolation room that follows the strict standards set forth by the Center for Disease Control and Prevention organization.

Find a Local Contractor

Request a Quote Online

negative pressure cleanroom, cleanrooms, modular cleanrooms, modular cleanroom construction, cleanroom construction, cleanroom, hardwall cleanrooms

This website use cookies to improve our products and your experience on our website by evaluating the use of our website, products and services, to personalize content, to provide social media features and to analyze our traffic. We also share information about your use of our website with our social media, advertising and analytics service providers. By agreeing to the use of cookies on our website, you direct us to disclose your personal information to these service providers for those purposes.

For more information, please see our Privacy Policy and, if you are a California resident, our Privacy Notice to California Residents.